Axpert ultra twin 11kw

Main Features :

  • Now With Voltronic Power
  • Dual outputs for smart load management
  • Two independent AC power sources connected and switched automatically Built-in current transformer sensor to meet
  • self-consumption application
  • Support external BTS (Battery Temperature Sensor) detection
  • Built-in power status lighting indicators
  • Built-in 2.8″ colored LCD with slide operation
  • Built-in Wi-Fi for mobile monitoring and OTA firmware upgrade
  • Reserved communication port for BMS (RS485, CAN-BUS or RS232)
  • Support optional GFCI, Rapid shutdown, AFCI detections
  • Supports USB On-the-Go function
  • Parallel operation with 6 units
  • 2 years warranty
Category:

Description

The Motoma 11 KW Solar Inverter is a high-performance, pure sine wave inverter designed to optimize your solar power system. Equipped with advanced features, it ensures reliable, efficient, and smart energy management for residential or commercial applications.

Inverter Data Sheet

MODELAxpert Ultra TWIN 8KAxpert Ultra TWIN 11K
Rated Power8000VA/8000W11000VA/11000W
Parallel CapabilityYES, 6 units
INPUT
Voltage230 VAC
Selectable Voltage Range170-280 VAC (For Personal Computers) ; 90-280 VAC (For Home Appliances)
Frequency Range50 Hz/60 Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode)230VAC ± 5%
Surge Power16000VA22000VA
Efficiency (Peak)93%
Transfer Time10 ms (For Personal Computers) ; 20 ms (For Home Appliances)
WaveformPure sine wave
BATTERY
Battery Voltage48 VDC
Floating Charge Voltage54 VDC
Overcharge Protection63 VDC
SOLAR CHARGER & AC CHARGER
Solar Charger TypeMPPT
Maximum PV Array Power10000W (5000W × 2)12000W (6000W × 2)
MPPT Range @ Operating Voltage90 ~ 450 VDC
Maximum PV Array Open Circuit Voltage500 VDC
Maximum PV Input Current27A × 2 (MAX 40A)
Maximum Solar Charge Current150A150A
Maximum AC Charge Current120A150A
Maximum Charge Current150A150A
PHYSICAL
Dimension, D x W x H (mm)145 × 438 × 553.6
Net Weight (kgs)18.4
Communication InterfaceUSB, RS232, RS485, WiFi, Dry-contact, BTS, Support optional GFCI, Rapid shutdown, AFCI detection
External Current Sensor PortYes, built-in current transformer sensor
OPERATING ENVIRONMENT
Humidity5% to 95% Relative Humidity(Non-condensing)
Operating Temperature-10°C to 50°C
Storage Temperature-15°C to 60°C
STANDARD
Compliance SafetyCE